V1-W-2M-PUR
  • Knurled nut suitable for tool assembly
  • Immunity to vibration, with mechanical latching
  • Gold-plated and machined contacts
  • Degree of protection IP67 / IP68 / IP69K
  • Halogen-free

Technical data of V1-W-2M-PUR General Specifications


Connector

More Details...

V1-G-2M-PUR
  • Knurled nut suitable for tool assembly
  • Immunity to vibration, with mechanical latching
  • Gold-plated and machined contacts
  • Degree of protection IP67 / IP68 / IP69K
  • Halogen-free

Technical data of V1-G-2M-PUR General Specifications



More Details...

NJ8-18GM-N

Switching function : Normally closed (NC) Output type : NAMUR Rated operating distance : 8 mm Installation : non-flush Assured operating distance : 0 ... 6.48 mm Reduction factor rAl : 0.4 Reduction factor rCu : 0.3 Reduction factor r304 : 0.


More Details...

NJ5-18GM-N

Switching function : Normally closed (NC) Output type : NAMUR Rated operating distance : 5 mm Installation : flush Assured operating distance : 0 ... 4.05 mm Reduction factor rAl : 0.21 Reduction factor rCu : 0.18 Reduction factor r304 : 0.


More Details...

NJ2-14GM-N-V1-Y19784

Switching function : Normally closed (NC) Output type : NAMUR Rated operating distance : 2 mm Installation : flush Assured operating distance : 0 ... 1.62 mm Reduction factor rAl : 0.4 Reduction factor rCu : 0.3 Reduction factor r304 : 0.


More Details...

NJ2-8GM-N-Y33681

Switching function : Normally closed (NC) Output type : NAMUR Rated operating distance : 2 mm Installation : non-flush Assured operating distance : 0 ... 1.62 mm Reduction factor rAl : 0.4 Reduction factor rCu : 0.3 Reduction factor r304 : 0.


More Details...

NCN4-12GM35-N0

Switching function : Normally closed (NC) Output type : NAMUR Rated operating distance : 4 mm Installation : non-flush Assured operating distance : 0 ... 3.24 mm Actual operating distance : 3.6 ... 4.4 mm typ. Reduction factor rAl : 0.37 Reduction factor rCu : 0.36 Reduction factor r304 : 0.


More Details...

NCB4-12GM40-N0-V1

Switching function : Normally closed (NC) Output type : NAMUR Rated operating distance : 4 mm Installation : flush Assured operating distance : 0 ... 3.24 mm Actual operating distance : 3.6 ... 4.4 mm typ. Reduction factor rAl : 0.41 Reduction factor rCu : 0.39 Reduction factor r304 : 0.


More Details...

NCB2-12GM35-N0

Switching function : Normally closed (NC) Output type : NAMUR Rated operating distance : 2 mm Installation : flush Assured operating distance : 0 ... 1.62 mm Actual operating distance : 1.8 ... 2.2 mm typ. Reduction factor rAl : 0.23 Reduction factor rCu : 0.21 Reduction factor r304 : 0.


More Details...

NBN4-12GM40-E2

Switching function : Normally open (NO) Output type : PNP Rated operating distance : 4 mm Installation : non-flush Output polarity : DC Assured operating distance : 0 ... 3.24 mm Reduction factor rAl : 0.45 Reduction factor rCu : 0.4 Reduction factor r304 : 0.


More Details...

NBB10-30GM50-E0

Switching function : Normally open (NO) Output type : NPN Rated operating distance : 10 mm Installation : flush Output polarity : DC Assured operating distance : 0 ... 8.1 mm Reduction factor rAl : 0.3 Reduction factor rCu : 0.3 Reduction factor r304 : 0.


More Details...

NBB8-18GM50-E0-V1

Switching function : Normally open (NO) Output type : NPN Rated operating distance : 8 mm Installation : flush Output polarity : DC Assured operating distance : 0 ... 6.48 mm Reduction factor rAl : 0.45 Reduction factor rCu : 0.4 Reduction factor r304 : 0.


More Details...

NBB8-18GM50-E0

Switching function : Normally open (NO) Output type : NPN Rated operating distance : 8 mm Installation : flush Output polarity : DC Assured operating distance : 0 ... 6.48 mm Reduction factor rAl : 0.45 Reduction factor rCu : 0.4 Reduction factor r304 : 0.


More Details...

NBB5-18GM60-A2-V1-3G+3D

Switching function : complementary Output type : PNP Rated operating distance : 5 mm Installation : flush Output polarity : DC Assured operating distance : 0 ... 4.05 mm Reduction factor rAl : 0.25 Reduction factor rCu : 0.15 Reduction factor r304 : 0.


More Details...

NBB5-18GM50-E2-V1

Switching function : Normally open (NO)
Output type : PNP
Rated operating distance : 5 mm
Installation : flush
Output polarity : DC
Assured operating distance : 0 ... 4.05 mm ( -25 ... 70 °C (-13 ...


More Details...

NBB4-12GM50-E2-V1

Switching function : Normally open (NO)
Output type : PNP
Rated operating distance : 4 mm
Installation : flush
Output polarity : DC
Assured operating distance : 0 ... 3.24 mm ( -25 ... 70 °C (-13 ...


More Details...

NBB4-12GM50-E2

Technical data of NBB4-12GM50-E2 General Specifications


Switching function   Normally open (NO) Output type   PNP Rated operating distance sn 4

More Details...

NBB4-12GM50-E0
  • Basic series
  • 4 mm flush
  • Increased operating distance
Switching Function : Normally Open (NO)
Output Type : NPN
Rated operating distance : 4mm
Output polarity : DC
Output type : 3-wire

Technical data of NBB4-12GM50-E0 General Specifications



More Details...