PEPPERL+FUCHS MALAYSIA SINGAPORE, PEPPERL+FUCHS SIGNAL CONVERTERS, PEPPERL+FUCHS JOHOR BAHRU
Selected tag
Tag Selection
- PEPPERL+FUCHS MALAYSIA SINGAPORE (56)
- PEPPERL+FUCHS JOHOR BAHRU (55)
- PEPPERL+FUCHS SIGNAL CONVERTERS (8)
- Switch Amplifier KFD2-SR2-Ex2.W (2)
- Frequency Converter with Trip Values KFD2-UFC-Ex1.D (1)
- KCD2-UT2-EX1 MALAYSIA SINGAPORE (1)
- KFD0-SD2-EX1.1045 MALAYSIA SINGAPORE (1)
- KFD2-SR2-EX1.W MALAYSIA SINGAPORE (1)
- KFD2-SR2-EX2.W MALAYSIA SINGAPORE (1)
- KFD2-STC4-EX1 MALAYSIA SINGAPORE (1)
- KFD2-STC4-EX2 MALAYSIA SINGAPORE (1)
- KFD2-UFC-EX1.D MALAYSIA SINGAPORE (1)
- KFD2-UT2-EX1 MALAYSIA SINGAPORE (1)
- SMART Transmitter Power Supply KFD2-STC4-Ex1 (1)
- SMART Transmitter Power Supply KFD2-STC4-Ex2 (1)
- Solenoid Driver KFD0-SD2-Ex1.1045 (1)
- Switch Amplifier KFD2-SR2-Ex1.W (1)
- Universal Temperature Converter KCD2-UT2-Ex1 (1)
- Universal Temperature Converter KFD2-UT2-Ex1 (1)
- 1-channel isolated barrier
- 24 V DC supply (Power Rail)
- Thermocouple, RTD, potentiometer or voltage input
- Current output 0/4 mA ... 20 mA
- Sink or source mode
- Configurable by PACTware
- Line fault (LFD) and sensor burnout detection
- Up to SIL 2 acc.
More Details...
- 1-channel isolated barrier
- 24 V DC supply (Power Rail)
- Input for NAMUR sensors or dry contacts
- Input frequency 1 mHz ... 5 kHz
- Current output 0/4 mA ...
More Details...
- 2-channel isolated barrier
- 24 V DC supply (Power Rail)
- Dry contact or NAMUR inputs
- Relay contact output
- Line fault detection (LFD)
- Reversible mode of operation
- Up to SIL 2 acc. to IEC 61508/IEC 61511
More Details...
- 1-channel isolated barrier
- 24 V DC supply (loop powered)
- Current limit 45 mA at 10 V DC
- Up to SIL 3 acc. to IEC 61508
Technical data of KFD0-SD2-Ex2.1045 General Specifications
Signal type Digital Output
- 1-channel isolated barrier
- 24 V DC supply (Power Rail)
- Thermocouple, RTD, potentiometer or voltage input
- Current output 0/4 mA ... 20 mA
- Sink or source mode
- Configurable by PACTware
- Line fault (LFD) and sensor burnout detection
- Up to SIL 2 acc.
More Details...
- 1-channel isolated barrier
- 24 V DC supply (Power Rail)
- Dry contact or NAMUR inputs
- Relay contact output
- Line fault detection (LFD)
- Reversible mode of operation
- Up to SIL 2 acc. to IEC 61508/IEC 61511
Technical data of KFD2-SR2-Ex1.
More Details...
- 2-channel isolated barrier
- 24 V DC supply (Power Rail)
- Input 2-wire SMART transmitters
- Output 0/4 mA ... 20 mA
- Terminals with test points
- Up to SIL 2 acc.
More Details...
- 1-channel isolated barrier
- 24 V DC supply (Power Rail)
- Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources
- Output 0/4 mA ... 20 mA
- Terminals with test points
- Up to SIL 2 acc.
More Details...