OMX 311UNI UNIVERSAL DIGITAL CONVERTER CONVERTER ( UNI > U/I )
The OMX 311UNI type is a galvanic isolated single-channel universal signal converter. It can be configured for 10 different input variants. Setting of both the input and output ranges can be done conveniently by a DIP switch located on the side of the housing or from a PC via the OM Link SW.
This device is based on a microprocessor with a 24-bit ∆∑ A/D converter, which guarantees high accuracy and excellent stability.
-
Multifunction input (DC, PM, RTD, T/C, DU)
-
Analogue output, passive/active
-
Quick configuration by DIP switch
-
PC configurable via USB port
-
Excitation 24 VDC
-
Galvanic isolation 2.5 kVAC
-
Simple instalation to DIN rail
-
Power supply 10…30 VDC, 24 VAC
Technical Data:
Input*Number of inputs1 inputDCRange±60 mV> 10 MOhmVstup 1±75 mV> 10 MOhmVstup 1±100 mV> 10 MOhmVstup 1±150 mV> 10 MOhmVstup 1±300 mV> 10 MOhmVstup 1±1000 mV> 10 MOhmVstup 1±20 V> 1 M?Vstup 2±40 V> 1 M?Vstup 2±100 mA> 200 mVVstup 3PMRange±5 mA< 200 mVInput 3±20 mA< 200 mVInput 3±2 V1 MOhmInput 2±5 V1 MOhmInput 2±10 V1 MOhmInput 24…20 mA< 200 mVInput 3OHMRange0…100 Ohm
0…300 Ohm
0…1 kOhm
0…3 kOhm
0…10 kOhm
0…30 kOhm
0…100 kOhm
0...300 kOhm (only for 2 or 4-wire connection)Connection2, 3 or 4-wireRTDTypePt 100/500/1000, 3850 ppm/°C-50°...450°CPt 100 3920 ppm/°C-50°...450°CPt 50 3910 ppm/°C-200°...1100°CPt 100 3910 ppm/°C-200°...450°CConnection2, 3 or 4-wireNTCTypeNTC1 2k2, B2585=3600 (-40°...125°C)
NTC2 2k0, B2585=3528 (-40°...125°C)
NTC3 10k, B2585=3435 (-40°...125°C)
NTC4 10k, B2585=3977 (-40°...125°C)
NTC5 12k, B2585=3740 (-40°...125°C)
NTC6 20k, B2585=4263 (-40°...125°C)Connection2, 3 or 4-wirePTCTypeKTY 81/210Conection2,3 or 4-wireNiTypeNi 1 000/10 000 s 5 000 ppm/°C-50°…250°CNi 1 000/10 000 s 6 180 ppm/°C-50°…250°CConnection2, 3 or 4-wireCuTypeCu 50/100 with 4 260 ppm/°C-50°…200°CCu 50/100 with 4 280 ppm/°C-200°…200°CConnection2-, 3-, or 4-wireDUPotentiometer power supply1,65 VDC/3 mA, odpor potenciometru > 500 OhmProjectionSignalizing LEDPWR, SET Device status signaling (RGB) SettingsControlThe device is controlled and set by a single button on the front panelOM LinkCompany communication interface for operation, setting and update of device firmware (microUSB)
OM Link program is also designed for visualization and filing of meas. values from more instrumentsInstrument accuracy and functionalityTemperature coefficient15 ppm/°CAccuracy±0,1 % z rozsahu (pro 20 měření/s)
±0,15 % z rozsahu (OHM - 100k/300k)Accuracy of cold junction measurement±1,5°CRate1…100 measur./sOverload capacity2x; 10x (t < 30 ms)Wire compensation (RTD, OHM)< 30 OhmLinearizationlineární interpolací v 100 bodech (pouze přes OM Link)Digital filtersarithmetic mean from 2…100 measurements floating mean from 2…30 measurements exponential mean from 2…100 measurements zaokrouhlení nastavení pevného kroku pro změnu hodnoty FunctionsTare designed to reset display on non-zero input signal Min/max value registration of min./max. value achieved during measurement Teach-in semiautomatic regime of input calibration Simulace simulace vstupního signálu/funkce přístroje Math. functionspolynom, invertní polynom, logarithm, exponential, power, rootWatch-dogreset after 500 msCalibrationat 25°C and 40 % r.h.Analogue outputsNumber of outputs1 outputTypeIsolated, programmable with resolution of max.10,000 steps, type and range are menu selectableTemperature coefficient15 ppm/°CNonlinearity±0,1 % of rangeRateresponse to value change < 160 µsRanges0…10 V / 10...0 V (resistive load > 2.6 kOhm), 0...20 mA, 4…20 mA / 20...4 mA (aktivní/pasivní)Compensation600 Ohm/12 VError stateerror message indication (<3.0 mA)Sensor excitationFixed24 VDC/35 mA, isolatedPower supplyPower supply10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolatedCurrent draw< 2,4 W/2,6 VAPower supply protectionPower supply is protected by a fuse inside the instrumentOperating conditionsConnectionconnector terminal board, cable section < 2,5 mm2Stabilization periodwithin 5 minutes after switch onOperating temperature-20°…60°CStorage temperature-20°…85°CProtection classIP20El. safetyEN 61010-1, A2Dielectric strength2,5 kVAC within 1 min. between pow. supply and input
2,5 kVAC po 1 min. mezi vstupem a výstupemInsulation resistancefor polution degree II, measuring cat. III.
napájení přístroje 300 V (ZI), 255 V (DI) input, output 300 V (ZI)* EMCEN61326-1: 2006Seismic capacityIEC/IEEE 60980-344 ed. 1.0:2020, par 6,9Mechanical propertiesMaterialPA 66, non-inflammable UL 94 V-0 (black)Dimensions48 x 24 x 72 mm (w x h x d)