COMITRONIC XORF-SA RFID-Coded Non-Autonomous Safety Switch



RFID-Coded Non-Autonomous Safety Switch for Safety Door Position Monitoring

The COMITRONIC XORF-SA RFID-Coded Non-Autonomous Safety Switch provides RFID-based position monitoring of safety doors on wheeled vehicles, featuring 16 million codes, automatic code learning and a maximum activation distance of up to 24 mm.

Designed for safety door monitoring applications, the XORF-SA uses RFID coding to detect the position of a corresponding actuator. The sensor is suitable for metallic environments and incorporates an auto-learning function that allows code programming without a computer or additional software.

As a non-autonomous safety switch, the XORF-SA is intended for integration with an appropriate safety controller. When combined with the specified AWAX controller, the original product information states that the system can achieve a performance level of up to PL e and safety category up to 4.

RFID Coding and Safety Door Detection

The XORF-SA incorporates RFID technology with approximately 16 million available codes. Its detection system is described in the original product information as "inviolable multicode" encoding.

The sensor supports automatic code learning without the use of software or a PC. An integrated LED indicates code recognition, allowing users to identify the recognition status during operation.

The maximum activation distance is specified as up to 24 mm. Installation conditions, mounting position and the relationship between sensor and actuator should be considered when configuring the safety door monitoring arrangement.

Safety Outputs and AWAX Controller Integration

The XORF-SA provides two redundant normally open (NO) contacts, rated at 50 mA / 30 V, together with one auxiliary PNP output rated at 50 mA.

According to the original product information, integration with an AWAX controller can provide a performance level of up to PL e and safety category up to 4 under EN 954-1. The stated MTTFd value is 40 years.

These safety performance figures relate to the specified controller arrangement and must not be interpreted as standalone safety ratings of the XORF-SA sensor. The complete safety function should be assessed according to its actual system configuration.

Mechanical Construction and Installation

The XORF-SA uses a PA6 housing with an IP68 sealing specification. The sensor is provided with a 50 cm PUR cable and M12 connector for electrical connection.

The original product information specifies two mounting positions using double wall brackets, together with four tamper-proof M4 attachment screws. A BH4 base option is also identified.

These construction and installation details should be considered when planning sensor placement, cable routing and actuator alignment.

Technical Specifications

Specification Details
Product and RFID Detection
Model XORF-SA
Product Type Non-Autonomous Safety Switch with RFID Coding
Application Position monitoring of safety doors on wheeled vehicles
RFID Coding 16 million codes
Detection Encoding Inviolable multicode, as described in the original product information
Code Programming Auto-learning without software or PC
Maximum Activation Distance Up to 24 mm
Metallic Environments Suitable
Indicator LED indicates code recognition
Reset Automatic
Electrical Outputs and Safety Performance
Safety Contacts 2 x redundant NO contacts, 50 mA / 30 V
Auxiliary Output 1 x PNP auxiliary output, 50 mA
Associated Safety Controller AWAX controller for the stated system safety performance
Performance Level Up to PL e with AWAX controller
Safety Category Up to Category 4 (EN 954-1) with AWAX controller
MTTFd 40 years, as stated in the original product information
Mechanical Construction and Connection
Housing Material PA6
Attachment 4 tamper-proof M4 screws (BH4 base option)
Mounting Positions 2 (double wall brackets)
Electrical Connection 50 cm PUR cable with M12 connector
Sealing IP68
Environmental Conditions
Ambient Temperature -30°C to +50°C
Storage Temperature -40°C to +85°C
Identification and Standards
Product Marking Pad printing and serial number for traceability
Certificate Reference E2 10R-04 14053 (UTAC)
ISO 7637-2 Pulse 1, 2a, 2b, 3a, 3b and 4

Features and Benefits

  • RFID-Coded Detection: Position monitoring using a system with 16 million RFID codes.
  • Automatic Code Learning: RFID code programming without additional software or a PC.
  • Metallic Environment Compatibility: Suitable for the metallic environments identified in the original product information.
  • Safety Controller Integration: Designed for non-autonomous operation with an appropriate safety controller.
  • Redundant Safety Contacts: Two redundant NO contacts and an auxiliary PNP output.
  • Recognition Indication: Integrated LED indicates RFID code recognition.
  • IP68 Sealing: Sealing rating specified for the sensor.
  • Defined Mounting Arrangement: Two mounting positions and tamper-proof attachment screw arrangement.
  • Traceability: Product marking includes a serial number.

Safety Switch Selection and Application Requirements

When selecting an RFID-coded safety switch, consider the safety door arrangement, required detection distance, electrical connection, environmental conditions and safety controller compatibility.

The XORF-SA provides RFID-coded position detection and redundant contacts for integration into a compatible safety control system. Its non-autonomous design means that the specified controller arrangement, complete safety circuit and installation requirements must be evaluated together.

For applications requiring a specific Performance Level or Safety Category, the complete safety function should be validated against the applicable system requirements. The stated PL e and Category 4 figures are conditional on the specified AWAX controller integration.

Discuss your safety door monitoring requirements, controller compatibility and installation conditions to determine whether the XORF-SA is suitable for your intended application.

Contact us today to enquire about the COMITRONIC XORF-SA RFID-Coded Non-Autonomous Safety Switch, discuss system requirements or obtain a quotation.



 Inquiry - COMITRONIC XORF-SA RFID-Coded Non-Autonomous Safety Switch