The OM 402 model series are 4 digit panel programmable instruments designed for maximum usefulness and user comfort while maintaining their fair price. Type OM 402PWR is a multifunction AC voltmeter and ammmeter with extended functions for further analysis of electricity network. It measures voltage, current, active power, frequency, and through calculation also reactive power, apparent power and cos fi. The instrument is based on a single-chip microcontroller and a true RMS converter, which ensure good accuracy, stability and easy operation of the instrument.
-
4 digit programmable projection
-
range: 0…1/2,5/5 A; 0…60/150/300 mV; 0…10/120/250/450 V
-
digital filters, tare, linearization
-
size of DIN 96 x 48 mm
-
power supply 10…30 V AC/DC or 80…250 V AC/DC
Options
-
comparators
-
data output
-
analog output
-
measured data record
-
three-color display - 20 mm
InputACRangepartially fixed, according to order
0…60 mV21 kOhmInput 1 - I0…150 mV21 kOhmInput 1 - I0…300 mV1,2 kOhmInput 1 - I0…1 A< 150 mVInput 1 - I0…2,5 A< 150 mVInput 1 - I0…5 A< 150 mVInput 1 - I0…10 V150 kOhmInput 2 - U0…120 V930 kOhmInput 3 - U0…250 V730 kOhmInput 2 - U0…450 V930 kOhmInput 3 - UInput frequency0…400 Hz
for amplitude from 8 VMeasured variablesVoltage (Vrms)
Current (Irms)
Real power (P-W)
Frequency (Hz)
with calculationProjectionDisplay range-99999…999999, single-coloured 14-segment LED
-999…9999, 3-coloured 7-segment LEDDisplay height14 mm, 20 mmDisplay colourred, green, red/green/orangeSignalizing LED1, 2, 3, 4 Limits L1, L2, L3, L4 (red) T Tare (green) M Min./Max. value (green) I, U, P, F Channels current, voltage, power, frequency (orange) Descriptionthe last two digits of the display can be used to display measured variables (only 14 mm display)Decimal pointmenu adjustable - fixed or floatingDisplay brightnessmenu adjustableDisplayed valuesKan I Value from channel I Fil. I Value from channel I after digital filter adjustment Kan U Value from channel U Fil. U Value from channel U after digital filter adjustment Kan P Value from channel P Fil. P Value from channel P after digital filter adjustment Kan F Value from channel F Fil. F Value from channel F after digital filter adjustment COS 02 Value from secondary channel ''cos fi'' Mat. Fn. Value of mathematical function Max. Maximum value Min. Minimum value SettingsControlThe device is controlled and set by five buttons on the front panel
Selected functions can also be controlled via external inputsMenuLIGHT contains only items necessary for basic device settings with password access PROFI Full device settings with password access USER User menu of any item, selected from LIGHT/PROFI. Access without password. Optional functionsButtons ''Left'', ''Up'', ''Down'', ''Enter'' can be assigned additional optional features
ZAKAZ button has no function NUL. M.M. Resetting Min/Max vaslues NUL. TA. Tare reset MENU Direct access to the selected menu item DOC. H. Temporary projection of selected values TARA Activating function Tare ULOZ Starting recording of the measured data into device memory NUL. PA. Resetting memory of the measured data OM LinkCompany communication interface for operation, setting and update of device firmware
OM Link program is also designed for visualization and filing of meas. values from more instrumentsInstrument accuracy and functionalityTemperature coefficient50 ppm/°CAccuracy0,3 % of range + 1 digit
(for projection 9999 and 5 measur./s)Rate0,5/1,2/2,5/5 measur./sOverload capacity2x; 10x (t < 30 ms) - not for > 250 V and 5 ALinearizationlinear interpolation in 50 points (only via OM Link)Digital filtersarithmetic mean from 2…100 measurements floating mean from 2…30 measurements exponential mean from 2…100 measurements rounding setting projection step for display FunctionsTare designed to reset display on non-zero input signal Min/max value registration of min./max. value achieved during measurement Peak value display shows only max. or min. values Math. functionspolynom, 1/x, logarithm, exponential, power, root, sin xData recordMeasured data recording into the memory
Not available in combination with with the data output MODBUSRTC period - 1 s…1 day, time-date-display value, < 266k data, 15 ppm/°C Watch-dogreset after 400 msCalibrationat 25°C and 40 % r.h.ComparatorsTypeDigital, menu adjustable, contact connect. < 30 msModeHysteresis switch. point, hysteresis band ''Mez ± 1/2 Hys.'' and time (0 ... 99.9 s) determ. switching delay From-To output interval ON and OFF Dose period, its multiples and time (0 ... 99.9 s), during which the output is active Output1x relay, switch-over contact (250 VAC/30 VDC, 3 A)
2x relay, switch-over contact (250 VAC/30 VDC, 3 A)
1x relay, switch on contact (250 VAC/30 VDC, 3A)
2x relay, switch on contact (250 VAC/30 VDC, 3 A)
2x bistable relay (250 VAC/30 VDC, 3A)
3x relay, 2x switch on + 1x switch-over contact (250 VAC/30 VDC, 3A)
4x relay, 2x switch on + 2x switch-over contact (250 VAC/30 VDC, 3A)
2x open collector (30 VDC/100 mA)
4x open collector (30 VDC/100 mA)
2x open collector (30 VDC/100 mA) + 2x relay, CO contact (250 VAC/30 VDC, 3 A)
2x SSR (250 VAC/1 A)Data outputsProtocolASCII, MESSBUS, MODBUS - RTU, PROFIBUS DPData format8 bits + no parity + 1 stop bit (ASCII)
7 bits + even parity + 1 stop bit (Messbus)Rate600…230 400 Baud
0,0096…12 MBaud (PROFIBUS)RS 232isolatedRS 485isolated, addressing max. 31 instrumentsAnalogue outputsTypeIsolated, programmable with a 16-bit D / A converter, type and range are menu selectableTemperature coefficient15 ppm/°CNonlinearity±0,1 % of rangeRateresponse to value change < 1 msRanges0...2 V, 0...5 V, 0...10 V, ±10 V, 0...5 mA, 0...20 mA, 4...20 mACompensation600 Ohm/12 V, 1 000 Ohm/24 VError stateat range of 4...20mA
error message indication (<3.0 mA)
Detection of current loop interruptionPower supplyPower supply10…30 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
80…250 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolatedCurrent draw< 9,4 W/9,2 VAPower supply protectionPower supply is protected by a fuse inside the instrumentOperating conditionsConnectionconnector terminal board, cable section < 1,5/2,5 mm2Operating temperature-20°…60°CStorage temperature-20°…80°CProtection classIP64 (front panel only)El. safetyEN 61010-1, A2Dielectric strength4 kVAC within 1 min. between pow. supply and input
4 kVAC within 1 min. between pow. supply and data/anal. output
4 kVAC within 1 min. between input and relay output
2,5 kVAC within 1 min.between input and data/anal. outputInsulation resistancefor polution degree II, measuring cat. III.
power supply 670 V (ZI), 300 V (Di)* input, output, PN 300 V (ZI), 150 V (Di)* EMCEN 61326-1Seismic capacityIEC 980: 1993, par.6Mechanical propertiesMaterialNoryl GFN2 SE1, non-inflammable UL 94 V-IDimensions96 x 48 x 120 mm (w x h x d)Panel cutout90,5 x 45 mm (w x h)