OM 402PWR



The OM 402 model series are 4 digit panel programmable instruments designed for maximum usefulness and user comfort while maintaining their fair price. Type OM 402PWR  is a multifunction AC voltmeter and ammmeter with extended functions for further analysis of electricity network. It measures voltage, current, active power, frequency, and through calculation also reactive power, apparent power and cos fi. The instrument is based on a single-chip microcontroller and a true RMS converter, which ensure good accuracy, stability and easy operation of the instrument.

  • 4 digit programmable projection
  • range: 0…1/2,5/5 A; 0…60/150/300 mV; 0…10/120/250/450 V
  • digital filters, tare, linearization
  • size of DIN 96 x 48 mm
  • power supply 10…30 V AC/DC or 80…250 V AC/DC

Options

  • comparators

  • data output

  • analog output

  • measured data record

  • three-color display - 20 mm
     

    Input
    AC
    Range
    partially fixed, according to order
    0…60 mV
    21 kOhm
    Input 1 - I
    0…150 mV
    21 kOhm
    Input 1 - I
    0…300 mV
    1,2 kOhm
    Input 1 - I
    0…1 A
    < 150 mV
    Input 1 - I
    0…2,5 A
    < 150 mV
    Input 1 - I
    0…5 A
    < 150 mV
    Input 1 - I
    0…10 V
    150 kOhm
    Input 2 - U
    0…120 V
    930 kOhm
    Input 3 - U
    0…250 V
    730 kOhm
    Input 2 - U
    0…450 V
    930 kOhm
    Input 3 - U
    Input frequency
    0…400 Hz
    for amplitude from 8 V
    Measured variables
    Voltage (Vrms)
    Current (Irms)
    Real power (P-W)
    Frequency (Hz)
    with calculation
    Projection
    Display range
    -99999…999999, single-coloured 14-segment LED
    -999…9999, 3-coloured 7-segment LED
    Display height
    14 mm, 20 mm
    Display colour
    red, green, red/green/orange
    Signalizing LED
    1, 2, 3, 4 Limits L1, L2, L3, L4 (red)
    T Tare (green)
    M Min./Max. value (green)
    I, U, P, F Channels current, voltage, power, frequency (orange)
    Description
    the last two digits of the display can be used to display measured variables (only 14 mm display)
    Decimal point
    menu adjustable - fixed or floating
    Display brightness
    menu adjustable
    Displayed values
    Kan I Value from channel I
    Fil. I Value from channel I after digital filter adjustment
    Kan U Value from channel U
    Fil. U Value from channel U after digital filter adjustment
    Kan P Value from channel P
    Fil. P Value from channel P after digital filter adjustment
    Kan F Value from channel F
    Fil. F Value from channel F after digital filter adjustment
    COS 02 Value from secondary channel ''cos fi''
    Mat. Fn. Value of mathematical function
    Max. Maximum value
    Min. Minimum value
    Settings
    Control
    The device is controlled and set by five buttons on the front panel
    Selected functions can also be controlled via external inputs
    Menu
    LIGHT contains only items necessary for basic device settings with password access
    PROFI Full device settings with password access
    USER User menu of any item, selected from LIGHT/PROFI. Access without password.
    Optional functions
    Buttons ''Left'', ''Up'', ''Down'', ''Enter'' can be assigned additional optional features
    ZAKAZ button has no function
    NUL. M.M. Resetting Min/Max vaslues
    NUL. TA. Tare reset
    MENU Direct access to the selected menu item
    DOC. H. Temporary projection of selected values
    TARA Activating function Tare
    ULOZ Starting recording of the measured data into device memory
    NUL. PA. Resetting memory of the measured data
    OM Link
    Company communication interface for operation, setting and update of device firmware
    OM Link program is also designed for visualization and filing of meas. values from more instruments
    Instrument accuracy and functionality
    Temperature coefficient
    50 ppm/°C
    Accuracy
    0,3 % of range + 1 digit
    (for projection 9999 and 5 measur./s)
    Rate
    0,5/1,2/2,5/5 measur./s
    Overload capacity
    2x; 10x (t < 30 ms) - not for > 250 V and 5 A
    Linearization
    linear interpolation in 50 points (only via OM Link)
    Digital filters
    arithmetic mean from 2…100 measurements
    floating mean from 2…30 measurements
    exponential mean from 2…100 measurements
    rounding setting projection step for display
    Functions
    Tare designed to reset display on non-zero input signal
    Min/max value registration of min./max. value achieved during measurement
    Peak value display shows only max. or min. values
    Math. functions
    polynom, 1/x, logarithm, exponential, power, root, sin x
    Data record
    Measured data recording into the memory
    RTC period - 1 s…1 day, time-date-display value, < 266k data, 15 ppm/°C
    Not available in combination with with the data output MODBUS
    Watch-dog
    reset after 400 ms
    Calibration
    at 25°C and 40 % r.h.
    Comparators
    Type
    Digital, menu adjustable, contact connect. < 30 ms
    Mode
    Hysteresis switch. point, hysteresis band ''Mez ± 1/2 Hys.'' and time (0 ... 99.9 s) determ. switching delay
    From-To output interval ON and OFF
    Dose period, its multiples and time (0 ... 99.9 s), during which the output is active
    Output
    1x relay, switch-over contact (250 VAC/30 VDC, 3 A)
    2x relay, switch-over contact (250 VAC/30 VDC, 3 A)
    1x relay, switch on contact (250 VAC/30 VDC, 3A)
    2x relay, switch on contact (250 VAC/30 VDC, 3 A)
    2x bistable relay (250 VAC/30 VDC, 3A)
    3x relay, 2x switch on + 1x switch-over contact (250 VAC/30 VDC, 3A)
    4x relay, 2x switch on + 2x switch-over contact (250 VAC/30 VDC, 3A)
    2x open collector (30 VDC/100 mA)
    4x open collector (30 VDC/100 mA)
    2x open collector (30 VDC/100 mA) + 2x relay, CO contact (250 VAC/30 VDC, 3 A)
    2x SSR (250 VAC/1 A)
    Data outputs
    Protocol
    ASCII, MESSBUS, MODBUS - RTU, PROFIBUS DP
    Data format
    8 bits + no parity + 1 stop bit (ASCII)
    7 bits + even parity + 1 stop bit (Messbus)
    Rate
    600…230 400 Baud
    0,0096…12 MBaud (PROFIBUS)
    RS 232
    isolated
    RS 485
    isolated, addressing max. 31 instruments
    Analogue outputs
    Type
    Isolated, programmable with a 16-bit D / A converter, type and range are menu selectable
    Temperature coefficient
    15 ppm/°C
    Nonlinearity
    ±0,1 % of range
    Rate
    response to value change < 1 ms
    Ranges
    0...2 V, 0...5 V, 0...10 V, ±10 V, 0...5 mA, 0...20 mA, 4...20 mA
    Compensation
    600 Ohm/12 V, 1 000 Ohm/24 V
    Error state
    at range of 4...20mA
    error message indication (<3.0 mA)
    Detection of current loop interruption
    Power supply
    Power supply
    10…30 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
    80…250 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
    Current draw
    < 9,4 W/9,2 VA
    Power supply protection
    Power supply is protected by a fuse inside the instrument
    Operating conditions
    Connection
    connector terminal board, cable section < 1,5/2,5 mm2
    Operating temperature
    -20°…60°C
    Storage temperature
    -20°…80°C
    Protection class
    IP64 (front panel only)
    El. safety
    EN 61010-1, A2
    Dielectric strength
    4 kVAC within 1 min. between pow. supply and input
    4 kVAC within 1 min. between pow. supply and data/anal. output
    4 kVAC within 1 min. between input and relay output
    2,5 kVAC within 1 min.between input and data/anal. output
    Insulation resistance
    for polution degree II, measuring cat. III.
    power supply 670 V (ZI), 300 V (Di)*
    input, output, PN 300 V (ZI), 150 V (Di)*
    EMC
    EN 61326-1
    Seismic capacity
    IEC 980: 1993, par.6
    Mechanical properties
    Material
    Noryl GFN2 SE1, non-inflammable UL 94 V-I
    Dimensions
    96 x 48 x 120 mm (w x h x d)
    Panel cutout
    90,5 x 45 mm (w x h)